Вызывная панель
Mode: Panel's operation mode.
Depending on the functional purpose of the panel, you must select the appropriate operating mode:
- Personal - when installing the panel in a private house or office with the ability to call the apartment at a logical address or P2P.
- Unit - when using the BA-series calling panels as well as the AV-01KD. For a set of apartments from the keyboard of the panel or by buttons.
- Wall - when using panels for direct dialing of the AM-02 concierge monitor.
Building: Building number.
Unit: Unit number.
Flor: Floor number.
Apartment: Apartment number.
Device number: Device enumeration number.
Numeration of the panels
If you have several call panels that have one logical address, then in the "No." field specify the values 2, 3, 4, 5, etc., up to 9.
SIP settings
Enable/Disable: Enable/disable SIP registration.
Proxy: A proxy SIP server that can be represented by both an IP address and a domain name.
Data format:
Before the proxy address, you must specify "sip:".
Server: SIP server address.
Data format:
Сan be represented by both an IP address and a domain name.
STUN IP: STUN server address.
Example:
STUN port: The port of the STUN server.
Example:
For google STUN server 19302 port is used.
Password: Password of SIP number.
Automatic re-registration: The function of automatic re-registration of the device on the server every N seconds. It may be useful in case of an unstable internet connection.
Re-registration interval: Input field for the time interval in seconds, after which the device will be re-registered on the SIP server.
Call settings
Concierge: Enable/disable the function to call the specified number in the "Number" line when pressing the concierge button.
Number: The direction to which the call will be made when pressing the concierge button.
If the function is not enabled, the concierge is called via an internal protocol. If the system has concierge monitors, the call will go to the main monitor. If he does not answer, the call will be transferred to the other monitors in the system.
Call max time: The time interval after which the panel will automatically end the outgoing call if there is no answer.
Talk max time: The time interval after which the panel will automatically end the outgoing call.
Auto answer: Enable/disable the automatic reception of a call for incoming calls to the panel. When the function is disabled, you must press the call button to answer.
End a call by pressing the button again: Enable/disable the function to automatically end a call when the button is pressed again.
Device settings
Video quality: Select your preferred video resolution.
RTP data profile: Select your preferred RTP data profile.
Volume Level: Adjusts the speaker volume of the panel.
Relay settings
Relay position: Selection of the initial state of the panel relay when the device is turned on. Selection of the initial state of the panel relay when the device is turned on. Switch when the device is turned on - when the device is turned on, the relay will switch the position to the opposite; when the device is turned off, the relay will return to its original position. Do not switch when the device is turned on - the relay will not switch the position when the device is turned on and off.